R410A is an HFC refrigerant blend widely used in compatible air-conditioning, heat-pump, and HVAC systems. This 25 lb R410A refrigerant cylinder is supplied new and factory sealed for professional servicing, maintenance, charging, and other permitted applications involving equipment designed for R410A.

In addition, Imperial Refrigerants provides reliable U.S. refrigerant supply with responsive customer support and purchasing options for individual cylinders, commercial quantities, and wholesale buyers.

Key Features of R410A Refrigerant

  • 25 lb factory-sealed cylinder
  • Refrigerant designation: R-410A
  • HFC refrigerant blend
  • Components: R32 / R125
  • Composition: 50% / 50%
  • ASHRAE safety classification: A1
  • Ozone depletion potential: 0
  • EPA Technology Transitions GWP: 2,088
  • Designed for compatible R410A air-conditioning and heat-pump systems
  • Suitable for servicing existing R410A equipment
  • New, factory-sealed packaging
  • Commercial and wholesale purchasing options available
  • Reliable U.S. supply

EPA identifies R410A as a 50/50 blend of R32 and R125. EPA’s current Technology Transitions reference table lists its GWP as 2,088.

R410A Refrigerant Applications

HVAC professionals use R410A to service compatible equipment originally designed and labeled for this refrigerant.

Typical applications may include:

  • Existing residential air-conditioning systems
  • Existing light-commercial air-conditioning systems
  • Existing central air-conditioning systems
  • Mini-split and multi-split systems designed for R410A
  • Heat-pump systems
  • Packaged rooftop HVAC equipment
  • Water-source and ground-source heat pumps
  • Other compatible HVAC equipment specifically designed for R410A

Before selecting or charging R410A, always verify the equipment manufacturer’s refrigerant specifications, required charge quantity, operating pressures, and applicable regulations.

For more options, explore our full range of refrigerants for additional HVAC/R applications.

R410A Refrigerant Properties

Specification R410A
Refrigerant R410A
Refrigerant Type HFC Blend
Components R32 / R125
Composition 50% / 50%
ASHRAE Safety Classification A1
Ozone Depletion Potential 0
Global Warming Potential 2,088*
Cylinder Size 25 lb
Condition New / Factory Sealed
Primary Application Existing Air Conditioning / Heat Pumps / HVAC
Charging Method Liquid Phase

*GWP value based on the current U.S. EPA Technology Transitions reference table.

R410A for Existing Air-Conditioning and Heat-Pump Systems

HVAC professionals continue to use R410A for servicing and maintaining compatible existing air-conditioning and heat-pump systems.

Existing R410A equipment may continue to operate and receive repairs throughout its useful life. Replacement components designed for R410A may also continue to be manufactured, imported, sold, and installed when they are used to service existing equipment.

Therefore, R410A remains an important service refrigerant for the large installed base of compatible air-conditioning and heat-pump systems in the United States.

EPA confirms that existing R410A systems can continue to be used, maintained, and repaired.

Current U.S. R410A Transition Considerations

R410A has a relatively high global warming potential of 2,088. As the United States transitions toward lower-GWP refrigerants, new residential and light-commercial air-conditioning and heat-pump systems are subject to a 700 GWP limit.

However, these rules do not prohibit the continued use and servicing of existing R410A equipment.

EPA also allows certain residential and light-commercial R410A systems manufactured or imported before January 1, 2025, to continue through applicable sell-through provisions. Components manufactured for servicing legacy R410A equipment may continue to be available subject to applicable labeling and regulatory requirements.

Therefore, R410A is primarily intended for servicing and maintaining compatible existing HVAC systems originally designed for this refrigerant. Always verify equipment specifications and applicable requirements before use.

R410A and R22 Systems

R410A and R22 have different operating pressures, refrigerant properties, lubricant requirements, and equipment designs. Therefore, technicians should not treat R410A as a direct retrofit replacement for R22.

Before converting an R22 system, a qualified HVAC/R professional should evaluate the complete equipment configuration and confirm that the proposed refrigerant and components are suitable for the application.

  • Compressor compatibility
  • System operating pressure
  • Lubricant requirements
  • Expansion devices
  • Refrigerant charge
  • Indoor and outdoor coils
  • System components
  • Manufacturer recommendations
  • Applicable regulatory requirements

EPA specifically notes that R410A is not listed under SNAP as an acceptable retrofit refrigerant for existing R22 systems.

R410A Charging and Service Considerations

R410A is a refrigerant blend consisting of R32 and R125.

Technicians should follow the refrigerant and equipment manufacturer’s charging procedures and generally remove R410A from the cylinder in the liquid phase to help maintain the intended refrigerant composition.

Always follow:

  • Equipment manufacturer specifications
  • Cylinder instructions
  • Refrigerant charge requirements
  • Proper recovery procedures
  • Approved HVAC/R service practices
  • Applicable EPA regulations

Only qualified professionals should service refrigeration and air-conditioning systems where certification is required.

Factory-Sealed 25 lb Cylinder

We supply each R410A cylinder in new, factory-sealed condition for professional HVAC/R service applications.

Moreover, factory-sealed packaging helps protect product integrity during storage, handling, and transportation.

For commercial buyers requiring multiple cylinders or recurring supply, contact our team for current inventory, quantity pricing, product documentation, and shipping options.

Why Buy R410A from Imperial Refrigerants?

Imperial Refrigerants supplies refrigerants for HVAC contractors, service companies, distributors, facility operators, and other qualified commercial buyers.

  • New factory-sealed cylinders
  • Reliable U.S. refrigerant supply
  • Commercial quantity purchasing
  • Wholesale pricing options
  • Fast order processing
  • Responsive customer support
  • Product documentation available upon request
  • U.S. delivery options

Wholesale R410A Refrigerant Supply

Need multiple 25 lb cylinders of R410A?

We support commercial and wholesale R410A refrigerant orders for HVAC contractors, service companies, distributors, facility maintenance operations, and other qualified commercial buyers.

In addition, our team can assist with current inventory, volume pricing, product documentation, and available shipping options.

U.S. R410A Purchase Requirements

R410A refrigerant sold for stationary air-conditioning and heat-pump service is subject to U.S. EPA refrigerant sales restrictions.

Purchasers generally must hold an appropriate EPA Section 608 Technician Certification or otherwise qualify as an authorized purchaser under applicable EPA requirements.

EPA also requires refrigerant sellers to verify purchaser eligibility and maintain applicable sales records.

Certification Notice: EPA Section 608 certification or other qualifying purchaser status may be required for R410A refrigerant purchases.

Important Use Information

Qualified HVAC/R professionals should handle, recover, charge, store, and use R410A in accordance with applicable EPA regulations, equipment manufacturer requirements, and established service procedures.

Always confirm that the specific equipment is designed and approved for R410A before use.

For current information regarding R410A and the U.S. HFC transition, refer to the U.S. EPA HFC Phasedown and Technology Transitions guidance.

Order R410A 25 lb Refrigerant

Looking for a reliable source of R410A in 25 lb cylinders?

Order online or contact Imperial Refrigerants for current inventory, product specifications, commercial quantities, and wholesale pricing.

Contact Us

Request Wholesale Quote

Refrigerant Type

R410A

Cylinder Size

25 lb

Refrigerant Classification

HFC Blend

Composition

R32 / R125 (50% / 50%)

ASHRAE Safety Class

A1

Ozone Depletion Potential

0

Global Warming Potential

2088

Condition

New / Factory Sealed

Application

Existing Air Conditioning / Heat Pumps / HVAC

Charging Method

Liquid Phase

Reviews

There are no reviews yet.

Be the first to review “R410A 25 lb Refrigerant – New Factory-Sealed Cylinder”

Your email address will not be published. Required fields are marked *

Scroll to Top